In the figure below, the team sketched approximately the timeline and modeled the rate of improvement of '''Energy Density''' by using a linear regression and S shape (Manually). With the current data, the technology's improvement rate is 1.326 [W-h/kg] per year.
In the figure below, the team sketched approximately the timeline and modeled the rate of improvement of '''Energy Density''' by using a linear regression and S shape (Manually). With the current data, the technology's improvement rate is 1.326 [W-h/kg] per year.
[[File:3BDES Energy Density Rate of Improvement.png]]


==Alignment with Company Strategic Drivers==
==Alignment with Company Strategic Drivers==

Revision as of 03:46, 12 October 2023

Technology Roadmap Sections and Deliverables

The Bioelectronic Devices for Electrical Stimulation [3BDES] is a level 3 technology roadmap focused around electrically stimulating biological systems (e.g., muscles, nerves, cells) for clinical purposes. A roadmap will be developed to explore the current status of the technology and the potential venues of progress from both a technical and business side.

Roadmap Overview

Bioelectronic Medicine is a novel approach that combines molecular medicine, neuroscience, and bioengineering to threaten and diagnose diseases and injuries. Bioelectronic devices can read and modulate electrical activity within the body. These devices open new possibilities and alternatives to diagnose and treat real-time diseases by using electrical pulses to restore health instead of chemical and biological drugs. In the literature, Bioelectronic Medicine can be found as neuromodulation, biostimulation, or electroceuticals. [1] [2] [3] ​

The bioelectronic devices that delivers electrical stimulation and dominate the market are: ​

  • Implantable Cardioverter Defibrillators (ICD)​
  • Cardiac Pacemakers (CP)​
  • Cochlear Implants (CI)​
  • Spinal Cord Stimulators (SCS)​
  • Deep Brain Stimulators (DBS)​
  • Sacral Nerve Stimulators (SNS)​
  • Transcutaneous Electrical Nerve Stimulators (TENS)​
  • Vagus Nerve Stimulators

Below is an example use case of a stimulator used for the spinal cord:

Spinal-Cord-Stimulation.jpg

Design Structure Matrix (DSM) Allocation

BDES Breakdown and DSM.jpg

The above breakdown of the technology shows different potential roadmaps of consideration within the wider Organism Stimulation level 1 roadmap. Since the technology that was selected is generic in nature (i.e. no particular target organism for stimulation), alternative venues of implementation such as chemical stimulation can be compared in the future. The enabling technologies are listed under the roadmap of interest (3BDES): Power Source (4PS: to power the electronic components), Pulse Generator (4PG: to emit the electric signals), Microcontroller (4MC: to receive, analyze, control the pulse generator, and communicate with an external device), Stimulation Sensors (4SS: to sense feedback signals from the target organism), and Stimulation Interfaces (4SI: to interface directly with the organism). The level 4 and 5 technologies within the 3BDES roadmap are interrelated by power flows and data flows as shown.

Roadmap Model using OPM

Provided below is an OPD and OPL of the 3BDES roadmap. The OPM shows the components that make up the device, their Figures of Merit (FOMs), and the functions that take place to stimulate the bio-signal and change its states.

File:3BDES OPD.png

Figures of Merit

The figure below lists the different FOMs that can be assessed for this technology roadmap. They are allocated by component (note that Telemetry refers to the Communications Module, assumed to be integrated into the Microcontroller).

File:3BDES FOMs List.png

In the figure below, the team sketched approximately the timeline and modeled the rate of improvement of Energy Density by using a linear regression and S shape (Manually). With the current data, the technology's improvement rate is 1.326 [W-h/kg] per year.

3BDES Energy Density Rate of Improvement.png

Alignment with Company Strategic Drivers

XXX

Positioning of Company vs. Competition

XXX

Technical Model

XXX

Financial Model

References

[1] Feinstein Institutes for Medical Research. (2023, September 18). Retrieved from: https://feinstein.northwell.edu/institutes-researchers/bioelectronic-medicine

[2] PNAS. (2023, September 18). Retrieved from: https://www.pnas.org/doi/10.1073/pnas.1919040116

[3] National Library of Medicine. (2023, September 18). Retrieved from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6057139/